Volts to Watts Calculator

Voltage is only half of a power figure, so this page supplies the other half and the reference numbers to check your answer against.

Voltage alone does not give you watts — you need the current as well.

Resistive loads are 1.0. Motors and compressors are typically 0.8.
60watts

Watts = Volts × Amps × Power factor

Volts to watts needs one more number than most people expect: the current. Watts equals volts multiplied by amps, so a 12V battery supplying 10 amps delivers 120 watts, while a 120V outlet at that same 10 amps delivers 1,200 watts. Voltage alone has no wattage attached to it.

The volts to watts formula, explained

Three quantities describe any circuit.

  • Volts are pressure, and they belong to the supply: a US socket near 120V, a vehicle battery near 12V, a lithium cell near 3.7V.
  • Amps are flow — the current the load pulls at that pressure. This one belongs to the appliance, and drops to zero when you switch it off.
  • Watts are the two multiplied: the unit every battery, inverter and solar specification is written in.

So a voltage on its own carries no wattage. A live 120V outlet with nothing plugged in delivers zero watts; put a kettle on it and it delivers 1,500.

The mistake almost everyone makes here. Treating a voltage as though it had a fixed wattage — searching “how many watts is 12V” and expecting a number back. Any converter that returns watts from a voltage alone has assumed a current on your behalf.

When you know resistance instead of current

For a purely resistive load — a heating element, an incandescent bulb — resistance substitutes for current: watts equals volts squared divided by ohms. A 120V element measuring 12 ohms dissipates 1,200W; a 12V element measuring 6 ohms dissipates 24W. The shortcut collapses on motors and switch-mode supplies, whose resistance shifts with load. Run it backwards for the watts to volts calculator and the watts to amps calculator.

Quick-reference conversion table

Supply voltages down the left, current across the top, watts in the body. Every figure assumes DC, or AC at a power factor of 1.0; for motors, use the power factor table below. Battery rows are nominal: a 12V lead-acid bank swings from about 11V flat to 14.6V on charge, so treat those as good to roughly 10%.

Supply voltage (nominal)At 1AAt 5AAt 10AAt 20AAt 30A
3.7V — single lithium cell3.7W18.5W37W74W111W
5V — USB-A5W25W50W100W150W
12V — car, RV, lead-acid bank12W60W120W240W360W
12.8V — LiFePO4 “12V” pack12.8W64W128W256W384W
20V — USB-C power delivery20W100W200W400W600W
24V — mid-size battery bank24W120W240W480W720W
36V — e-bikes, cordless tools36W180W360W720W1,080W
48V — off-grid and home banks48W240W480W960W1,440W
51.2V — LiFePO4 “48V” pack51.2W256W512W1,024W1,536W
110V — low end of US mains110W550W1,100W2,200W3,300W
120V — US mains120W600W1,200W2,400W3,600W
230V — European mains230W1,150W2,300W4,600W6,900W
240V — US large-appliance circuit240W1,200W2,400W4,800W7,200W

Every cell is the same multiplication, so it scales cleanly: 120V at 7A is simply 840W. The bottom row catches people out. 240V at 30A is 7,200W, which is why a dryer is not a load a portable unit takes on.

Why this conversion decides what you buy

Products are sold in watts and watt-hours, but nearly every component that limits what you can do is rated in volts and amps. Converting connects the two.

Battery banks

Amp-hours mean nothing until a voltage is attached. A 100Ah bank at 12V nominal stores roughly 1,200Wh; the same 100Ah in a LiFePO4 pack at 12.8V stores about 1,280Wh; at 48V it stores four times as much again. Identical headline number, three different purchases. The amp-hours to watt-hours calculator does that step.

Solar panels and charge controllers

A panel’s wattage is its maximum-power voltage multiplied by its current there: a nominal 12V panel works near 18V at 5.5A in full sun, which is where the 100W label comes from. The controller is rated in amps, which is a hidden wattage ceiling. A 30A controller charging a 12V battery at 14.4V tops out near 430W of array; on a 24V bank at 28.8V it handles about 860W. Buy 600W of panel for that controller on 12V and a third is wasted daily. Our solar sizing guide covers the array.

Inverters and the DC current problem

The conversion also tells you what happens on the battery side of an inverter. Run a 1,000W AC load through one that is 90% efficient and the battery must supply about 1,111W. Divide by the system voltage:

  • At 12V, roughly 93 amps — heavy cable, hot terminals, measurable voltage drop.
  • At 24V, roughly 46 amps.
  • At 48V, roughly 23 amps.

Same watts, same job, a quarter of the current. That is why serious off-grid systems moved to 48V, and why 12V is a poor foundation for a 3,000W inverter. A finished unit settles that internally, leaving continuous output as the figure you choose. The power station finder filters on output and capacity together, and the catalogue is on the power stations page.

On the numbers. Capacity and output are manufacturer specifications. Expect 80–90% of rated capacity in real use after inverter losses, and less in cold weather.

AC, DC and power factor

On DC — batteries, solar panels, 12V appliances — volts multiplied by amps gives watts exactly. The same holds on AC with a resistive load: kettles, toasters, heating elements, incandescent bulbs.

Motors, compressors, pumps and cheap switching supplies do not. Their voltage and current drift out of step, so the circuit carries more current than the delivered power accounts for. Volts multiplied by amps then gives volt-amps, apparent power; real watts are that figure multiplied by the power factor, a number between 0 and 1. Below, one circuit under six loads.

Load type at 120V and 12APower factorApparent powerReal watts
Heater, kettle, incandescent bulb1.01,440 VA1,440W
Electronics with active correction0.951,440 VA1,368W
Well-corrected mixed household load0.91,440 VA1,296W
Fridge compressor, pump, power tool0.81,440 VA1,152W
Lightly loaded motor0.71,440 VA1,008W
Older uncorrected supply0.61,440 VA864W

Two habits fall out of that table. Sizing a battery, assume a power factor of 1.0: it overstates consumption rather than understating it. Sizing an inverter, use the real figure, because an inverter is limited by the current it passes. The VA to watts calculator does that directly.

Size the inverter on volt-amps, not on watts. A power factor of 0.7 makes a load look smaller in watts while the inverter still supplies all 1,440 volt-amps. Sizing on the smaller figure is how people end up with a unit that trips under a load it was rated for.

Safe continuous load and the 80% rule

Multiplying a circuit’s voltage by its breaker rating needs one correction. Under US electrical code a continuous load — anything drawing for three hours or more — may occupy only 80% of the breaker rating. Convert, then take four fifths.

CircuitTheoretical maximumSafe continuous (80%)
120V, 15A breaker1,800W1,440W
120V, 20A breaker2,400W1,920W
120V, 30A RV hookup3,600W2,880W
240V, 30A breaker7,200W5,760W
240V, 50A breaker12,000W9,600W
12V bank, 30A fuse360W288W
12V bank, 100A BMS limit1,200W960W
24V bank, 100A BMS limit2,400W1,920W
48V bank, 100A BMS limit4,800W3,840W

The 20A row is highlighted because most households quietly rely on it: a 1,920W continuous budget, which a 1,500W space heater plus a 700W microwave has already overrun. The 30A RV row explains the other familiar complaint, since 2,880W is why air conditioning plus a microwave trips a pedestal.

The DC rows work differently. No code rule derates a battery management system, but the same discipline pays, because a BMS current limit is a wattage ceiling in disguise: a 12V pack with a 100A BMS cannot deliver much beyond 1,200W whatever inverter is bolted to it. Treat a power station the same way. A unit rated 2,000W holds 2,000W, but running near 1,600W leaves surge headroom for a compressor start.

Do not use this arithmetic to plan fixed wiring. Breaker sizing, conductor gauge and continuous-load rules depend on cable run, insulation type and ambient temperature, and they are a licensed electrician’s problem. These figures are for sizing portable equipment.

Frequently asked questions

How do you convert volts to watts?

Multiply the voltage by the current in amps. 12V at 5A is 60 watts; 120V at 10A is 1,200 watts. On AC, multiply that by the power factor — 1.0 for heating elements, around 0.8 for motors. Voltage alone will not convert.

How many watts is 12 volts?

12 volts is not a wattage by itself; it depends on the current drawn. At 1A it is 12W, at 5A 60W, at 10A 120W, at 30A 360W and at 100A 1,200W. Take the amp rating off the appliance label and work from that.

How many watts is 120 volts?

A 120V supply delivers 120 watts for every amp drawn, so a 15A circuit tops out at 1,800W and a 20A circuit at 2,400W. Design to 80% of those figures for anything running three hours or more: 1,440W and 1,920W.

Can you convert volts to watts without amps?

Only if you know the resistance. For a purely resistive load, watts equals volts squared divided by ohms, so 120V across a 12-ohm element is 1,200W. For a motor or a switch-mode supply the resistance is not fixed and the shortcut gives a wrong answer.

How many watts is 5V 2A?

10 watts, which is a standard USB-A phone charger. USB-C power delivery negotiates higher voltages to push more power down the same cable: 9V at 3A is 27W, 15V at 3A is 45W, 20V at 5A is 100W. The voltage does the work.

Does 240V give twice the watts of 120V?

At the same current, yes: 240V at 20A is 4,800W against 2,400W at 120V. But an appliance built for 240V draws half the current for the same job, so its wattage is unchanged and only the current halves. That lower current is the real benefit.

What is the formula for three-phase volts to watts?

Multiply line voltage by line current by the power factor, then by the square root of three, roughly 1.732. A 208V three-phase circuit at 20A with a power factor of 0.9 delivers about 6,485W. Portable power stations are single-phase, so this arises only on commercial supplies.

Next step. Once every load is converted into watts, add them up and turn the total into a capacity and an output rating with our power station sizing guide.